Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702748

RESUMEN

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Asunto(s)
Placas Óseas , Hilos Ortopédicos , Fijación Interna de Fracturas , Fracturas Óseas , Huesos del Metacarpo , Huesos del Metacarpo/lesiones , Huesos del Metacarpo/cirugía , Humanos , Fenómenos Biomecánicos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía
2.
J Orthop Surg Res ; 18(1): 934, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38057807

RESUMEN

BACKGROUND: A variety of surgical techniques had been developed over the past few decades for treating thumb carpometacarpal joint (CMCJ) osteoarthritis (OA). However, there are currently no accepted consensus on the ideal treatment for thumb CMCJ OA. Arthrodesis was one of the widely popular treatment methods; however, studies have showed that non-union rates were as high as 50%, with higher complications such as osteoarthritis of neighbouring joints and higher revision surgeries required as compared to other surgical methods. Patients with arthrodesis were also reported to have decreased thumb range of motion and loss of opponens function. Currently, there are numerous intraoperative positioning techniques for arthrodesis which could be confusing for young surgeons. With recent developments of fixation plates and better understanding of the wrist anatomy, this retrospective review aimed to evaluate the efficacy of our intraoperative hand-grip positioning method for arthrodesis of thumb CMCJ OA. What are the postoperative functional outcomes of (1) T-hook plates and (2) our intraoperative hand-grip positioning method for Eaton III thumb CMCJ OA arthrodesis by evaluating pain visual analogue scale (VAS) score, Disabilities of the Arm, Shoulder and Hand questionnaires (DASH), Mayo Wrist scores, capability of thumb opposition (Kapandji score), and comparing pre- and postoperative grip and pinch strength? METHODS: Twenty patients with CMCJ OA underwent arthrodesis using our intraoperative hand-grip positioning method and T-hook plates and screws (Acumed, USA). Patients were evaluated preoperatively and at 1, 3, 6 and 12 months postoperatively. Radiologic assessment including fusion evaluation, evaluation of radial and palmar abduction angles was done on hand X-rays. RESULTS: Twenty patients with a minimum follow-up duration of 12 months were included in this study. 100% fusion rate was achieved with only 1 case of complication involving radial sensory nerve neuropathy which was resolved after removal of implant and neurolysis. Significant improvement in pain and Mayo Wrist scores were noted 3 months postoperatively, whilst DASH score exhibited significant improvements after 6 months of follow-up (p < 0.05). Even though there were no significant differences observed between preoperative and postoperative grip strength, pinch strength and Kapandji scores, positive recovery trends were noted for all parameters with these functions surpassing preoperative levels after 12 months of follow-up. Significant improvements on hand X-rays were also noted for both postoperative radial and palmar abduction angles. CONCLUSIONS: There is currently no consensus on the ideal treatment method for thumb CMCJ OA. In this study, we would like to propose a simple intraoperative hand-grip positioning method with T-hook plates for arthrodesis. As seen from our results, our technique was able to provide satisfactory and replicable postoperative results and thus we would like to propose our hand-grip positioning method with T-hook plates fixation for subsequent treatment of patients with Eaton stage III thumb CMCJ OA.


Asunto(s)
Articulaciones Carpometacarpianas , Osteoartritis , Humanos , Artrodesis/métodos , Articulaciones Carpometacarpianas/cirugía , Fuerza de la Mano , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Dolor , Rango del Movimiento Articular , Pulgar/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
3.
Medicine (Baltimore) ; 102(36): e34981, 2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37682204

RESUMEN

Metacarpal neck fracture is one of the most common types of hand fractures; the literature suggests that applying a bone plate on the dorsal side provides higher fixation strength than that provided by other fixation methods. However, bone plate fixation on the dorsal side may result in postoperative tendon adhesion. So far, no studies have investigated the fixation of metacarpal neck fractures on the volar side by using a bone plate. The objective of this study was to investigate the differences in the fixation results between bone plate fixation on the dorsal side and bone plate fixation on the volar side of the metacarpal in the case of a metacarpal neck fracture. A saw blade was used to create a transverse metacarpal neck fracture on 14 artificial metacarpal bone specimens. The specimens were divided into 2 groups depending on the fixation method: a volar locking plate (VLP) group and a dorsal locking plate (DLP) group. All specimens were subjected to a cantilever bending test on a material testing system, and a force-displacement curve was used to measure the yield force and stiffness, which served as an indicator of the fixation ability of the 2 fracture fixation methods. For the experimental results, the Mann-Whitney U test was used to compare the fixation abilities of the 2 fixation methods. In terms of yield force, the DLP group (266.9 ± 68.3 N) scored significantly higher than the VLP group (32.6 ± 2.7 N) (P < .05); expressed in terms of median, the DLP group scored 8.2 times higher than the VLP group. Similarly, in terms of stiffness, the DLP group (69.0 ± 13.4 N/mm, median ± interquartile range) scored significantly higher than the VLP group (12.9 ± 1.4 N/mm) (P < .05); expressed in terms of median, the DLP group scored 5.3 times higher than the VLP group. The fixation strength of volar bone plates is only about one-third of that of dorsal bone plates.


Asunto(s)
Fracturas Óseas , Traumatismos de la Mano , Huesos del Metacarpo , Fracturas de la Columna Vertebral , Humanos , Placas Óseas , Huesos del Metacarpo/cirugía , Fracturas Óseas/cirugía , Cuello
4.
BMC Musculoskelet Disord ; 24(1): 33, 2023 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-36650507

RESUMEN

BACKGROUND: The digital artery-based V-Y advancement flap is a widely used flap for soft tissue coverage in the treatment of flexion contracture of the proximal interphalangeal (PIP) joint. A standard method for the flap design and a mathematical method to predict the advance distance have not been well established. In this study, we proposed a simplified method for the design of V-Y advancement flaps based on digital arteries and used a geometric model to predict the advance distance for the flexion contracture correction surgery. METHODS: According to the general concept of hand flap design and law of cosine, we proposed three principles in the design of the digital artery-based V-Y advancement flap that should be followed. Since 2021 to 2022, finger geometric data of 120 fingers (index, middle, ring, and small fingers) from 30 healthy participants were collected and analysed to evaluate the necessary advance distance and flap tip angle for PIP flexion contracture correction of different fingers by our flap design method. RESULTS: The middle finger needed a significantly longer advance distance compared to other fingers in the same degree flexion contracture correction. The ring finger had the largest length-to width ratio and smallest flap tip angle among the four fingers in the V-Y flap design. No vertical scar crossed the flexion creases and flap tip angle < 20° was found in the tentative V-Y flap design for the 120 fingers. CONCLUSIONS: Our flap design method provides a proper advance distance and flap length-to-width ratio without common skin complications in the flap design for PIP flexion contracture of index, middle, ring and small fingers. This geometric model provides a mathematical basis for prediction of advance distance and flap tip angle in the design of a digital artery-based V-Y advancement flap.


Asunto(s)
Contractura , Traumatismos de los Dedos , Humanos , Traumatismos de los Dedos/cirugía , Resultado del Tratamiento , Contractura/cirugía , Dedos , Articulaciones de los Dedos/cirugía , Arteria Cubital
5.
World J Clin Cases ; 10(22): 7960-7967, 2022 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-36158474

RESUMEN

BACKGROUND: Ewing's sarcoma is a highly malignant primary bone tumor that commonly affects children. For young patients, multidisciplinary treatment and limb salvage are recommended, and surgical plans considering the growth potential and bone activity after tumor resection are essential. CASE SUMMARY: An 11-year-old Asian boy had a 1-mo history of a right-sided limping gait. Imaging revealed a proximal tumor with bone destruction and physeal involvement over the right femoral neck. He was diagnosed with stage IV (T1N0M1aG3) Ewing's sarcoma with bilateral lung metastases. Neoadjuvant chemotherapy decreased the tumor size and confined it to the metaphyseal region. The patient underwent four stages of surgery: wide tumor excision plus reconstruction with vascular fibular bone graft plus internal fixation; repeat open reduction and internal fixation; femoral lengthening with orthosis after physeal maturity; and orthosis removal and bone elongation (approximately 6 cm). Following surgery, he could walk without discomfort and had almost equal-sized bilateral femoral heads, indicating physis preservation. The surgery was successful, and normal femoral head growth was achieved after complete remission. The patient was able to resume normal activities with equal length of the bilateral lower limbs. CONCLUSION: Tumor treatment and reconstruction following resection are important in skeletally immature patients with Ewing's sarcoma to improve quality of life.

6.
J Orthop Surg Res ; 17(1): 374, 2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35922799

RESUMEN

OBJECTIVE: To investigate differences in the effectiveness of two lag screws, a regular bone plate, and locking bone plate fixation in treating horizontal oblique metacarpal shaft fractures. MATERIALS AND METHODS: Horizontal oblique metacarpal shaft fractures were created in 21 artificial metacarpal bones and fixed using one of the three methods: (1) two lag screws, (2) a regular plate, and (3) a locking plate. All the specimens were subjected to the cantilever bending test performed using a material testing machine to enable recording of the force-displacement data of the specimens before failure. The Kruskal-Wallis test was used to compare failure force and stiffness values among the three fixation methods. RESULTS: The mean failure force of the two lag screw group (78.5 ± 6.6 N, mean + SD) was higher than those of the regular plate group (69.3 ± 17.6 N) and locking plate group (68.2 ± 14.2 N). However, the mean failure force did not significantly differ among the three groups. The mean stiffness value of the two lag screw group (17.8 ± 2.6 N/mm) was lower than those of the regular plate group (20.2 ± 10.5 N/mm) and locking plate group (21.8 ± 3.8 N/mm). However, the mean stiffness value did not significantly differ among the three groups. CONCLUSION: The fixation strength of two lag screw fixation did not significantly differ from that of regular and locking bone plate fixation, as indicated by the measurement of the ability to sustain force and stiffness.


Asunto(s)
Fracturas Óseas , Traumatismos de la Mano , Huesos del Metacarpo , Fenómenos Biomecánicos , Placas Óseas , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Humanos , Huesos del Metacarpo/lesiones , Huesos del Metacarpo/cirugía
7.
J Orthop Surg Res ; 17(1): 72, 2022 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-35123532

RESUMEN

BACKGROUND: For oblique metacarpal shaft fracture, if anatomical reduction is achieved through conservative cast immobilization rather than stable fixation, bone malrotation can easily occur, resulting in severe loss in hand prehensile function. However, whether bone plate fixation or only lag screw fixation is more preferable remains unclear. Few studies have evaluated whether screw fixation can provide biomechanical fixation strength similar to bone plate fixation. OBJECTIVE: We assessed the difference in fixation strength between fixtation with two lag screws and bone plate for oblique metacarpal shaft fractures. MATERIALS AND METHODS: We created oblique metacarpal shaft fractures on 21 artificial bones and fixated them using (1) double lag screw (2LS group), (2) regular plate (RP group), or (3) locked plate (LP group). To obtain the force-displacement data, a cantilever bending test was conducted for each specimen through a material testing machine. One-way analysis of variance and a Tukey test were conducted to compare the maximum fracture force and stiffness of the three fixation methods. RESULTS: The maximum fracture force of the 2LS group (mean + SD: 153.6 ± 26.5 N) was significantly lower than that of the RP (211.6 ± 18.5 N) and LP (227.5 ± 10.0 N) groups (p < 0.001). However, no significant differences were discovered between the RP and LP groups. The coefficient of variation for the maximum fracture force of the 2LS group (17.3%) was more than twice as high as that of the RP (8.7%) and LP (4.4%) groups. In addition, the stiffness of the three fixation methods was similar. CONCLUSION: Compared with bone plate fixation, double lag screw fixation yielded slightly lower maximum bearable fracture force but similar stiffness. Therefore, this technique could be used for treating oblique metacarpal shaft fractures. However, using double lag screw fixation alone is technically demanding and requires considerable surgical experiences to produce consistent results.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Traumatismos de la Mano , Huesos del Metacarpo/cirugía , Fenómenos Biomecánicos , Fracturas Óseas/diagnóstico por imagen , Humanos , Huesos del Metacarpo/diagnóstico por imagen , Huesos del Metacarpo/lesiones
8.
Arthroscopy ; 38(6): 1846-1856, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35042008

RESUMEN

PURPOSE: To evaluate the outcomes of "tent form" triangular fibrocartilage complex (TFCC) repair combined with dorsal distal radioulnar joint (DRUJ) capsule imbrication for posttraumatic chronic DRUJ instability. METHODS: All patients treated with arthroscopic "tent form" TFCC repair and DRUJ capsule imbrication from 2016 to 2019 were retrospectively reviewed. The inclusion criteria were symptomatic chronic DRUJ instability for >6 months and dorsal DRUJ subluxation on magnetic resonance imaging. The Disabilities of the Arm, Shoulder, and Hand score, Patient-Rated Wrist Evaluation, grip strength, Modified Mayo Wrist Score, range of motion, and distal radioulnar joint stability were assessed for a minimum of 2 years postoperatively. RESULTS: Thirty-eight patients were included in the final analysis. The average follow-up duration was 35.6 months (range, 24-48 months). The 24-month postoperative grip strengths and 3-dimensional motions of wrist were not significantly different from that of the nonoperated wrist. Compared with their preoperative status, Disabilities of the Arm, Shoulder, and Hand score, Patient-Rated Wrist Evaluation, and Modified Mayo Wrist Score indicated the significant improvement with P values of .001, .001, and .002, respectively. CONCLUSIONS: In chronic DRUJ instability with a loosening dorsal capsule, "tent form" TFCC transcapsular repair combined with DRUJ capsule imbrication restored the integrity of TFCC and dorsal DRUJ capsule and achieved a promising outcome. We recommend this procedure as an option of treatment for patients with posttraumatic chronic DRUJ instability. LEVEL OF EVIDENCE: IV, case series.


Asunto(s)
Inestabilidad de la Articulación , Fibrocartílago Triangular , Traumatismos de la Muñeca , Artroscopía/efectos adversos , Humanos , Cápsula Articular/cirugía , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Fibrocartílago Triangular/cirugía , Traumatismos de la Muñeca/cirugía , Articulación de la Muñeca/cirugía
9.
PNAS Nexus ; 1(4): pgac188, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36714857

RESUMEN

An ongoing debate regarding the evolution of morality is whether other species show precursory moral behavior. The veil of ignorance (VOI) paradigm is often used to elicit human moral judgment but has never been tested in other primates. We study the division of resources behind the VOI in Formosan macaques. Monkeys choose the equal division more often when a conspecific is present than when it is absent, suggesting a degree of impartiality. To better understand this impartiality, we measure a monkey's reactions to two directions of inequity: one regarding inequity to its advantage and the other to its disadvantage. We find that disadvantageous inequity aversion correlates with the degree of impartiality behind the VOI. Therefore, seemingly impartial behavior could result from a primitive negative reaction to being disadvantaged. This suggests a mechanism to explain a tendency toward impartiality.

10.
Medicine (Baltimore) ; 100(39): e27375, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34596154

RESUMEN

ABSTRACT: Metacarpal shaft fractures are common hand fractures. Although bone plates possess strong fixation ability, they have several limitations. The use of headless compression screws for fracture repair has been reported, but their fixation ability has not been understood clearly.This study aimed to compare the fixation ability of locked plate with that of headless compression screw for metacarpal fracture repair.A total of 14 artificial metacarpal bones (Sawbones, Vashon, WA, USA) were subjected to transverse metacarpal shaft fractures and divided into 2 groups. The first group of bones was fixed using locked plates (LP group), whereas the second group was fixed using headless compression screws (HC group). A material testing machine was used to perform cantilever bending tests, whereby maximum fracture force and stiffness were measured. The fixation methods were compared by conducting a Mann-Whitney U test.The maximum fracture force of the HC group (285.6 ±â€Š57.3 N, median + interquartile range) was significantly higher than that of the LP group (227.8 ±â€Š37.5 N; P < .05). The median of the HC group was 25.4% greater. However, no significant difference in stiffness (P > .05) was observed between the HC (65.2 ±â€Š24.6 N/mm) and LP (61.7 ±â€Š19.7 N/mm) groups.Headless compression screws exhibited greater fixability than did locked plates, particularly in its resistance to maximum fracture force.


Asunto(s)
Placas Óseas/normas , Tornillos Óseos/normas , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Huesos del Metacarpo/lesiones , Humanos , Ensayo de Materiales/métodos , Modelos Anatómicos
11.
J Orthop Surg Res ; 16(1): 441, 2021 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-34233702

RESUMEN

BACKGROUND: Metacarpal shaft fractures are a common hand trauma. The current surgical fixation options for such fractures include percutaneous Kirschner wire pinning and nonlocking and locking plate fixation. Although bone plate fixation, compared with Kirschner wire pinning, has superior fixation ability, a consensus has not been reached on whether the bone plate is better placed on the dorsal or lateral side. OBJECTIVE: The purpose of this study was to evaluate the fixation of locking and regular bone plates on the dorsal and lateral sides of a metacarpal shaft fracture. MATERIALS AND METHODS: Thirty-five artificial metacarpal bones were used in the experiment. Metacarpal shaft fractures were created using a saw blade, which were then treated with four types of fixation as follows: (1) a locking plate with four locking bicortical screws on the dorsal side (LP_D); (2) a locking plate with four locking bicortical screws on the lateral side (LP_L); (3) a regular plate with four regular bicortical screws on the dorsal side (RP_D); (4) a regular plate with four regular bicortical screws on the lateral side (RP_D); and (5) two K-wires (KWs). All specimens were tested through cantilever bending tests on a material testing system. The maximum fracture force and stiffness of the five fixation types were determined based on the force-displacement data. The maximum fracture force and stiffness of the specimens with metacarpal shaft fractures were first analyzed using one-way analysis of variance and Tukey's test. RESULTS: The maximum fracture force results of the five types of metacarpal shaft fracture were as follows: LP_D group (230.1 ± 22.8 N, mean ± SD) ≅ RP_D group (228.2 ± 13.4 N) > KW group (94.0 ± 17.4 N) > LP_L group (59.0 ± 7.9 N) ≅ RP_L group (44.5 ± 3.4 N). In addition, the stiffness results of the five types of metacarpal shaft fracture were as follows: LP_D group (68.7 ± 14.0 N/mm) > RP_D group (54.9 ± 3.2 N/mm) > KW group (20.7 ± 5.8 N/mm) ≅ LP_L group (10.6 ± 1.7 N/mm) ≅ RP_L group (9.4 ± 1.2 N/mm). CONCLUSION: According to our results, the mechanical strength offered by lateral plate fixation of a metacarpal shaft fracture is so low that even KW fixation can offer relatively superior mechanical strength; this is regardless of whether a locking or nonlocking plate is used for lateral plate fixation. Such fixation can reduce the probability of extensor tendon adhesion. Nevertheless, our results indicated that when lateral plate fixation is used for fixating a metacarpal shaft fracture in a clinical setting, whether the mechanical strength offered by such fixation would be strong enough to support bone union remains questionable.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Huesos del Metacarpo/lesiones , Huesos del Metacarpo/cirugía , Fenómenos Biomecánicos , Humanos , Ensayo de Materiales
12.
BMC Musculoskelet Disord ; 22(1): 431, 2021 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-33971840

RESUMEN

BACKGROUND: Metacarpal shaft fractures are a common type of hand fracture. Despite providing strong fixation strength, plate fixation has numerous shortcomings. Concerning internal fixation with Kirschner wires (K-wires), although this approach is frequently used to treat metacarpal shaft fractures, the lack of functional stability may result in fixation failure. OBJECTIVE: To evaluate the effect of figure-of-eight cerclage wire on fixation for transverse metacarpal shaft fractures using two K-wires. MATERIALS AND METHODS: We used a saw blade to create transverse metacarpal shaft fractures in 14 fourth-generation artificial third metacarpal bones (Sawbones, Vashon, WA, USA), which were assigned to groups undergoing fixation with two K-wires (KP) or with two K-wires and figure-of-eight cerclage wire (KP&F8). All specimens were subjected to material testing, specifically cantilever bending tests. The maximum fracture force and stiffness of the two fixation types were determined on the basis of the force-displacement data. The Mann-Whitney U test was used to compare between-group differences in maximum fracture force and stiffness. RESULTS: The maximum fracture force of the KP group (median ± interquartile range = 97.30 ± 29.70 N) was significantly lower than that of the KP&F8 group (153.2 ± 69.50 N, p < 0.05; Figure 5a), with the median of the KP&F8 group exceeding that of the KP group by 57.5%. Similarly, stiffness was significantly lower in the KP group (18.14 ± 9.84 N/mm) than in the KP&F8 group (38.25 ± 23.49 N/mm; p < 0.05; Figure 5b), with the median of the KP&F8 group exceeding that of the KP group by 110.9%. CONCLUSION: The incorporation of a figure-of-eight cerclage wire increased the maximum fracture force and stiffness by 57.5 and 110.9%, respectively, compared with those achieved in standard two K-wire fixation. Therefore, hand surgeons are advised to consider the proposed approach to increase fixation strength.


Asunto(s)
Fracturas Óseas , Huesos del Metacarpo , Placas Óseas , Hilos Ortopédicos , Fijación Interna de Fracturas , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Humanos , Huesos del Metacarpo/diagnóstico por imagen , Huesos del Metacarpo/cirugía
13.
World J Clin Cases ; 9(10): 2302-2311, 2021 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-33869607

RESUMEN

BACKGROUND: Chondrosarcoma, a cartilage matrix producing tumor, is the second most commonly observed primary bone tumor after osteosarcoma, accounting for 15% of all chest wall malignancies. We herein report the case of a patient with chondrosarcoma of the sternum and our management of the chest wall defects that presented following radical tumor resection. CASE SUMMARY: A 31-year-old patient presented to our hospital with dull pain and a protruding mass overlying the chest for 3 mo. The presence of nocturnal pain and mass size progression was reported, as were overhead arm elevation-related limitations. Computed tomography showed a focal osteoblastic mass in the sternum with bony exostosis and adjacent soft tissue calcification. Positron emission tomography-computed tomography revealed hypermetabolic activity with a mass located over the upper sternum. Magnetic resonance imaging showed a focal ill-defined bony mass of the sternum with cortical destruction and periosteal reaction. Preoperative biopsy showed a consistent result with chondrosarcoma with immunohistochemical positivity for S100 and focal positivity for IDH-1. The grade II chondrosarcoma diagnosis was confirmed by postoperative pathology. The patient underwent radical tumor resection and chest wall reconstruction with a locking plate and cement spacer. The patient was discharged 1 wk after surgery without any complications. At the 1-year follow-up, there was no local recurrence on imaging. The functional scores, including Constant Score, Nottingham Clavicle Score, and Oxford Shoulder Score, showed the absence of pain in the performance of daily activities or substantial functional disabilities. CONCLUSION: The diagnosis of chondrosarcoma must be considered when chest wall tumors are encountered. The surgical reconstructive materials, with a locking plate and cement spacer, used in our study are cost-effective and readily-available for the sternum defect.

14.
BMC Musculoskelet Disord ; 22(1): 281, 2021 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-33726740

RESUMEN

BACKGROUND: The treatment of mallet fracture using hook plate fixation was first introduced in 2007 and has subsequently shown excellent outcomes. Common complications, such as nail deformity and screw loosening, have also been reported. Very few studies have focused on these common complications or their prevention. In this study, we present the clinical outcomes and complications of our case series and describe the pitfalls and detailed solution of surgical tips to avoid common complications related to this procedure. METHODS: The retrospective case series of 16 patients with mallet fractures who underwent open reduction and hook plate fixation in our hospital from 2015 to 2020 were retrospectively reviewed. Data on extension lag, range-of-motion (ROM) of the distal interphalangeal joint (DIP) joint, the Disabilities of the Arm, Shoulder, and Hand (DASH) score, and surgical complications were collected and analysed. The clinical outcome was graded according to the Crawford mallet finger criteria. RESULTS: Sixteen patients were included in our analysis. The median DIP extension lag was 0° (range, 0° to 30°) and the median active DIP flexion angle was 60° (range, 40° to 90°). The median DASH score was 0 (range, 0-11.3). Fourteen patients with good and excellent results were satisfied with this treatment. The Complication rate in our patient series was 18%. Common complications reported in articles included wound necrosis, extension lag, nail deformity, and plate loosening. CONCLUSIONS: Despite the fact that the treatment of mallet fracture with hook plate fixation has satisfactory functional outcomes, pitfalls, including iatrogenic nail germinal matrix injury, unnecessary soft tissue dissection, and insufficient screw purchase, were still reported. To avoid complications, we suggest modifications of the skin incision, soft tissue dissection, and screw position.


Asunto(s)
Falanges de los Dedos de la Mano , Placas Óseas , Fijación Interna de Fracturas/efectos adversos , Humanos , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento
15.
BMC Musculoskelet Disord ; 22(1): 146, 2021 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-33546670

RESUMEN

BACKGROUND: Metacarpal shaft fracture is a common fracture in hand trauma injuries. Surgical intervention is indicated when fractures are unstable or involve considerable displacement. Current fixation options include Kirschner wire, bone plates, and intramedullary headless screws. Common complications include joint stiffness, tendon irritation, implant loosening, and cartilage damage. OBJECTIVE: We propose a modified fixation approach using headless compression screws to treat transverse or short-oblique metacarpal shaft fracture. MATERIALS AND METHODS: We used a saw blade to model transverse metacarpal neck fractures in 28 fresh porcine metacarpals, which were then treated with the following four fixation methods: (1) locked plate with five locked bicortical screws (LP group), (2) regular plate with five bicortical screws (RP group), (3) two Kirschner wires (K group), and (4) a headless compression screw (HC group). In the HC group, we proposed a novel fixation model in which the screw trajectory was oblique to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; thus, the screw did not damage the articular cartilage. The specimens were tested using a modified three-point bending test on a material testing system. The maximum fracture forces and stiffness values of the four fixation types were determined by observing the force-displacement curves. Finally, the Kruskal-Wallis test was adopted to process the data, and the exact Wilcoxon rank sum test with Bonferroni adjustment was performed to conduct paired comparisons among the groups. RESULTS: The maximum fracture forces (median ± interquartile range [IQR]) of the LP, RP, HC, and K groups were 173.0 ± 81.0, 156.0 ± 117.9, 60.4 ± 21.0, and 51.8 ± 60.7 N, respectively. In addition, the stiffness values (median ± IQR) of the LP, HC, RP, and K groups were 29.6 ± 3.0, 23.1 ± 5.2, 22.6 ± 2.8, and 14.7 ± 5.6 N/mm, respectively. CONCLUSION: Headless compression screw fixation provides fixation strength similar to locked and regular plates for the fixation of metacarpal shaft fractures. The headless screw was inserted obliquely to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; therefore the articular cartilage iatrogenic injury can be avoidable. This modified fixation method may prevent tendon irritation and joint cartilage violation caused by plating and intramedullary headless screw fixation.


Asunto(s)
Fracturas Óseas , Huesos del Metacarpo , Animales , Fenómenos Biomecánicos , Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Huesos del Metacarpo/diagnóstico por imagen , Huesos del Metacarpo/cirugía , Porcinos
16.
BMC Musculoskelet Disord ; 21(1): 734, 2020 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-33172435

RESUMEN

BACKGROUND: The aim of this study is to introduce a new method of percutaneous endoscopic decompression under 3D real-time image-guided navigation for spinal stenosis in degenerative kyphoscoliosis patients without instability or those who with multiple comorbidities. Decompression alone using endoscope for kyphoscoliosis patient is technical demanding and may result in unnecessary bone destruction leading to further instability. The O-arm/StealthStation system is popular for its ability to provide automated registration with intraoperative, postpositioning computed tomography (CT) which results in superior accuracy in spine surgery. METHODS: In this study, we presented four cases. All patients were over seventy years old female with variable degrees of kyphoscoliosis and multiple comorbidities who could not endure major spine fusion surgery. Percutaneous endoscopic unilateral laminotomy and bilateral decompression under 3D real-time image-guided navigation were successfully performed. Patients' demographics, image study parameters, and outcome measurements including pre- and post-operative serial Visual analog scale (VAS), and Oswestry Disability Index (ODI) were well documented. The follow-up time was 1 year. RESULTS: Pre- and post-operative MRI showed average dural sac cross sectional area (DSCSA) improved from 81.62 (range 67.34-89.07) to 153.27 (range 127.96-189.73). Preoperative neurological symptoms including radicular leg pain improved postoperatively. The mean ODI (%) were 85 (range 82.5-90) at initial visit, 35.875 (range 25-51) at 1 month post-operatively, 26.875 (range 22.5-35) at 6 months post-operatively and 22.5 (range 17.5-30) at 12 months post-operatively (p < 0.05). The mean VAS score were 9 (range 8-10) at initial visit, 2.25 (range 2-3) at 1 month post-operatively, 1.75 (range 1-2) at 6 months post-operatively and 0.25 (range 0-1) at 12 months post-operatively (p < 0.05). There was no surgery-related complication. CONCLUSIONS: To the best of our knowledge, this is the first preliminary study of percutaneous endoscopic laminotomy under O-arm navigation with successful outcomes. The innovative technique may serve as a promising solution in treating spinal stenosis patients with lumbar kyphoscoliosis and multiple comorbidities.


Asunto(s)
Estenosis Espinal , Cirugía Asistida por Computador , Anciano , Descompresión Quirúrgica , Femenino , Humanos , Imagenología Tridimensional , Laminectomía , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Estenosis Espinal/complicaciones , Estenosis Espinal/diagnóstico por imagen , Estenosis Espinal/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
17.
Medicine (Baltimore) ; 99(26): e20862, 2020 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-32590787

RESUMEN

RATIONALE: Talar fracture accompanied with malleolar fracture is rare, and its management is complex. Ankle soft tissue is much thinner than other parts of the human body, and the shape of the ankle makes wounds difficult to close immediately after surgery, which may result in poor skin condition if the wound tension is too high. However, joint congruity and osteonecrosis are the main concerns of talar fracture. PATIENT CONCERNS: A 57-year-old man presented at the emergency department following a motorcycle accident. DIAGNOSES: Physical examination revealed swelling and tenderness of the left ankle and midfoot. The patient had comminuted talar fracture and was indicated for dual-screw fixation or even plate with screw fixation. INTERVENTIONS: We performed single screw fixation after assessing the soft tissue condition and employed a technique of using continuous longitudinal force to bring together fracture fragments (ankle ligamentotaxis) during surgery. Open reduction with a mini-hook plate and tension band wire was used for bimalleolar fracture repair using the combined anteromedial and anterolateral approach with extension of the incision. Kirschner wire for temporary fixation was performed using ligamentotaxis, and a 2.4 headless screw was inserted from the posteromedial to the anterolateral direction. OUTCOMES: The patient was discharged with a standard short leg splint and was instructed not to bear weight on the affected ankle for 2 months. The patient walked well without discomfort, and the Hawkins sign was clearly visible. Single screw fixation preserves the integrity of the talus bone as minimal space is used for this operative technique. Single screw fixation preserves more bony stock when most of the internal fixator is located within the bone. Additionally, surgery time is shorter than multiple implantations even when performing the same procedure; as a result, there was less ankle soft tissue swelling. LESSONS: This case provides evidence of using the single screw fixation technique for addressing both malleolar and talar fractures, and that talar fracture management can be less aggressive with limited weight bearing and initial limited range of motion given the presence of malleolar fracture. The alignment and stability of bony fragments also benefit from ankle ligamentotaxis.


Asunto(s)
Fracturas de Tobillo/diagnóstico , Accidentes de Tránsito , Fracturas de Tobillo/cirugía , Placas Óseas , Hilos Ortopédicos , Servicio de Urgencia en Hospital/organización & administración , Humanos , Masculino , Persona de Mediana Edad , Motocicletas , Reducción Abierta/métodos , Astrágalo/cirugía , Tomografía Computarizada por Rayos X/métodos
18.
Biomed Res Int ; 2019: 7196528, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31828123

RESUMEN

BACKGROUND: The pedicle screw is one of the main tools used in spinal deformity correction surgery. Robotic and navigated surgeries are usually used, and they provide superior accuracy in pedicle screw placement than free-hand and fluoroscopy-guided techniques. However, their high cost and space limitation are problematic. We provide a new solution using 3D printing technology to facilitate spinal deformity surgery. METHODS: A workflow was developed to assist spinal deformity surgery using 3D printing technology. The trajectory and profile of pedicle screws were determined on the image system by the surgical team. The engineering team designed drill templates based on the bony surface anatomy and the trajectory of pedicle screws. Their effectiveness and safety were evaluated during a preoperative simulation surgery. The surgery consisted in making a pilot hole through the drill template on a computed tomography- (CT-) based, full-scale 3D spine model for every planned segment. Somatosensory evoke potential (SSEP) and motor evoke potential (MEP) were used for intraoperative neurophysiological monitoring. Postoperative CT was obtained 6 months after the correction surgery to confirm the screw accuracy. RESULTS: From July 2015 to November 2016, we performed 10 spinal deformity surgeries with 3D printing technology assistance. In total, 173 pedicle screws were implanted using drill templates. No notable change in SSEP and MEP or neurologic deficit was noted. Based on postoperative CT scans, the acceptable rate was 97.1% (168/173). We recorded twelve pedicle screws with medial breach, six with lateral breach, and five with inferior breach. Medial breach (12/23) was the main type of penetration. Lateral breach occurred mostly in the concave side (5/6). Most penetrations occurred above the T8 level (69.6%, 16/23). CONCLUSION: 3D printing technology provides an effective alternative for spinal deformity surgery when expensive medical equipment, such as intraoperative navigation and robotic systems, is unavailable.


Asunto(s)
Procedimientos Neuroquirúrgicos/instrumentación , Tornillos Pediculares , Impresión Tridimensional , Enfermedades de la Médula Espinal/cirugía , Adolescente , Adulto , Niño , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Robótica/instrumentación , Enfermedades de la Médula Espinal/diagnóstico por imagen , Enfermedades de la Médula Espinal/fisiopatología , Fusión Vertebral/instrumentación , Cirugía Asistida por Computador/instrumentación , Tomografía Computarizada por Rayos X , Adulto Joven
19.
Exp Appl Acarol ; 77(1): 105-115, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30488157

RESUMEN

Hard ticks infesting canine hosts were determined for the first time in northern Taiwan. Between May 2010 and April 2011, a total of 9467 ticks were collected from 2025 dogs. They were identified based on pictorial keys of their morphological characteristics. These ticks belong to three genus and six species: Rhipicephalus sanguineus, R. haemaphysaloides, Haemaphysalis hystricis, H. lagrangei, H. formosensis and Ixodes ovatus. Rhipicephalus sanguineus was the most dominant species (92.5%), followed by H. hystricis (4.6%), R. haemaphysaloides (2.3%), I. ovatus (0.54%), H. lagrangei (0.04%) and H. formosensis (0.01%). The overall density was 4.7 ticks per dog (ranging from 1.8 to 20.8) and the highest seasonal prevalence was observed in September with an average density of 8.2 ticks per dog. Our results not only provide the first survey of hard ticks infesting dogs in northern Taiwan, but also highlight the possible impact of these tick species on human health.


Asunto(s)
Enfermedades de los Perros/epidemiología , Ixodidae/fisiología , Infestaciones por Garrapatas/veterinaria , Animales , Enfermedades de los Perros/parasitología , Perros , Femenino , Ixodidae/crecimiento & desarrollo , Larva/crecimiento & desarrollo , Larva/fisiología , Masculino , Ninfa/crecimiento & desarrollo , Ninfa/fisiología , Taiwán/epidemiología , Infestaciones por Garrapatas/epidemiología , Infestaciones por Garrapatas/parasitología
20.
Acta Trop ; 166: 356-362, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27686959

RESUMEN

Babesia gibsoni was firstly identified in Rhipicephalus sanguineus ticks infested on dogs in Asia. A total of 1195 ticks collected from veterinary practitioners and pet clinics were examined for Babesia by nested-polymerase chain reaction assay based on the 18S small subunit ribosomal RNA (ssrRNA) gene. Babesia infection was detected in nymph, male and female ticks with an infection rate of 2.42%, 0.98% and 1.97%, respectively. Sequence and phylogenetic analysis revealed that these Babesia spp. were genetically affiliated to the same clades within the genospecies of B. gibsoni and B. vogeli, and can be discriminated from other genospecies of Babesia. Intra- and inter-species analysis based on the genetic distance (GD) values indicated a lower level in B. gibsoni (GD<0.011) compared with other genospecies of Babesia (GD>0.106) and out-group protozoa (GD>0.244). This study provides the first molecular evidence of B. gibsoni identified in nymphs of R. sanguineus ticks in Asia, and further confirms the detection of B. vogeli in nymphs and adults of R. sanguineus in northern Taiwan. The epizootiological significance of canine Babesia spp. transmitted by R. sanguineus tick needs to be further identified.


Asunto(s)
Babesia/genética , Babesiosis/parasitología , Enfermedades de los Perros/parasitología , Rhipicephalus sanguineus/parasitología , Animales , Asia , Babesiosis/transmisión , Enfermedades de los Perros/transmisión , Perros , Femenino , Masculino , Ninfa/parasitología , Filogenia , Reacción en Cadena de la Polimerasa/veterinaria , ARN Protozoario/análisis , ARN Ribosómico 18S/análisis , Taiwán
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...